Silicone rubber flat cable

First, product features and uses

This product uses silicone rubber as insulation or sheathing material. Because silicone rubber itself has the characteristics of high temperature resistance, cold resistance, softness, wear resistance and anti-corrosion, the cable has stable electrical properties under high temperature environment, good anti-aging performance and long service life. It is suitable for AC 1KV and below mobile transmission equipment such as driving, trolley, transmission machinery and other power transmission lines and control, lighting and communication lines. This product has been widely used in metallurgy and electric power. , chemical, ship, port and other industries.

The split-phase shielded silicone rubber sheathed flat cable is suitable for use as a power supply cable for the inverter.


Second, product implementation standards

Q/HHTZH007.4


Third, the use of characteristics

1, AC rated voltage:U0/U 0.6/1KV,Maximum working temperature: 180°C, minimum ambient temperature: fixed laying -60°C

2. The cable installation temperature should not be lower than -25°C.


Fourth, the basic model and name

model

product name

YGGB

Flat flexible cable for silicone rubber insulation and sheath movement

YGCB-VFR

Nitrile insulated silicon rubber sheathed flat flexible cable for mobile

YGCB-F46R

F46 insulated silicone rubber sheathed flat flexible cable

YGCBP

Silicone rubber insulated and sheathed tinned copper wire braided phase-shielded shielded flat flexible cable

YGCB-VFRP

Nitrile insulated silicon rubber sheathed tinned copper wire braided phase-shielded shielded flat flexible cable

YGCB-F46RP

F46 insulated silicon rubber sheathed tinned copper wire braided phase-shielded shielded flat flexible cable

Note: The copper wire in the conductor core can be tinned.


Five: code name and meaning

Code

Code meaning

Y

Mobile series

G

Silicone rubber insulation or sheath

VF

Nitrile insulation or sheath

B

Flat type

P

Copper wire (tinned copper wire) shielding

F46

Polyperfluoroethylene propylene


Six main technical indicators       

1. The finished cable conductor (R type) DC resistance (in accordance with GB/T3956) refers to Table 2 of Appendix A.

2. The insulation resistance at 20°C is not less than 100 MΩ·KM.

3, the finished cable is subjected to AC 50Hz  3.5KV/5minThe voltage test does not break down.


Schematic

YGCBSchematic

1.jpg

YGCBPSchematic

2.jpg