First, product features and uses
This product has the characteristics of cold resistance, softness, wear resistance, oil resistance, etc. It is suitable for connecting cables for mobile electrical appliances with AC rated voltage of 0.6/1KV and below with special requirements of cold resistance and oil resistance. At present, this product has been widely used in metallurgy and electric power. , ships, automobile manufacturing and other industries.
Two: product implementation standards
Q/HHTZH007.1
Flame retardant performance test executionGB/T12666-2008Regulation
Third, the use of characteristics
1, AC rated voltage:U0/U 0.6/1kV,Maximum working temperature: 105°C, minimum ambient temperature: fixed laying temperature should not be lower than -60°C
2. The cable installation temperature should not be lower than -25°C.
3, the cable allows bending radius: the cable is at least 12 times the outer diameter of the cable
Four: basic model and name
model | product name |
YVFR | Nitrile insulated and sheathed power flexible cable |
YVFRP | Nitrile insulated and sheathed copper braided shielded power flexible cable |
Remark: ZR is added before the flame retardant cable type, and the copper wire in the conductor core can be tinned.
Five: code name and meaning
Code | Code meaning |
Y | Mobile series |
VF | Nitrile insulation and sheath |
P | Copper braided shield |
R | Stranded conductor |
Six main technical indicators
1. Finished cable conductor (R type) DC resistance (in accordance with GB/T3956)
2. The insulation resistance at 20°C is not less than 50MΩ·kM.
3. The finished cable is subjected to AC 50Hz 3.5kV/5min voltage test without breakdown.
Schematic