Mobile light flexible cable for coal mine

This product is designed according to MT818-2009 "Cables for Coal Mine", MYQ-0.3/0.5 meets the performance index of MT818.9-2009.


range

This product is suitable for copper core mobile light flexible cable for coal mine with rated voltage U0/U of 0.3/0.5kV.


Type

Cable type is shown in Table 1.

Table 1

model

name

use

MYQ-0.3/0.5

Mobile light rubber sheathed flexible cable for coal mine

Underground mine roadway lighting, conveyor interlock and control and signal no power connection


Cable structure as shown

1.jpg

Cable specification

Table 2

Number of cores x conductor nominal cross section mm²

Nominal thickness mm

Cable outer diameter mm

Number of cores x conductor nominal cross section mm²

Nominal thickness mm

Cable outer diameter mm

insulation

jacket

MYQ-0.3/0.5

insulation

jacket

MYQ-0.3/.05

2x1.0
2x1.5
2x2.5
3x1.0
3x1.5
3x2.5
4x1.0
4x1.5

0.6
0.8
1.0
0.6
0.8
1.0
0.6
0.8

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

7.5~10.0
9.0~11.5
10.5~13.5
8.4~10.5
9.5~12.0
11.5~13.5
9.0~11.0
10.5~13.0

4x2.5
7x1.0
7x1.5
7x2.5
12x1.0
12x1.5
12x2.5

1.0
0.6
0.8
1.0
0.6
0.8
1.0

2.0
1.5
2.0
2.0
2.0
2.5
2.5

13.5~16.5
10.5~13.0
13.0~16.5
15.5~19.0
14.0~17.5
18.0~21.5
21.0~25.5

    

skills requirement

conductor

The conductor shall be attached to the provisions of 5.1 of MT818.1-2009. The single conductor of the conductor is allowed to be tinned, and the surface of the conductor may be provided with an isolation layer.

Note: Discoloration or embrittlement of the barrier layer after vulcanization is not evaluated.


insulation

Insulation shall be in accordance with the provisions of XJ-30A in GB/T7594.8-1987, the tensile strength shall not be less than 6.5 MPa, and the insulation thickness shall be in accordance with 5.2.2 of MT818.1-2009 and Table 2 of this part. The insulation resistance of the insulated power core at 20 °C shall not be less than 650 MΩ·km.


Cable core

The strand diameter ratio of the cable core should be no more than 10.


jacket

The sheath is a single-layer structure, and the performance of the sheath shall be in accordance with the XH-03A type in GB/T7594.7-1987. The thickness of the sheath shall be in accordance with the provisions of MT818.1-1999 and Table 2 of this part.


Outer diameter

Cable outer diameter values should be within the ranges listed in Table 2.


Working conditions

The rated voltage U0/U is 0.3/0.5kV, the long-term allowable operating temperature of the cable conductor is 90°C, and the minimum bending radius of the cable is 6 times the diameter of the cable.