Standard wall thickness low smoke zero halogen flame retardant cable

use

This product is suitable for AC rated voltage of 750V and below. The distribution system, control system and signal system of various rolling stock and urban rail metro vehicles are especially suitable for use in small space and other electrical equipment with flame retardant requirements.


Conditions of Use

Cable rated working voltage U0/U: 450750V;

The long-term allowable operating temperature of the cable should not exceed 125°C.


Model and name introduction

model

Rated voltage

product name

WDZ-DC/Ⅲ-125

750V

Low smoke zero halogen flame retardant standard wall thickness insulation, mineral oil and fuel oil resistant, temperature resistant 125 ° C, 750 V cable

WDZ-DC-H/Ⅲ-125

750V

Low halogen-free flame retardant standard wall thickness insulation, standard thickness sheath, resistant to mineral oil and fuel oil, temperature resistant 125 ° C, 750 V cable

WDZ-DC-ZP-H/Ⅰ-125

750V

Low smoke zero halogen flame retardant standard wall thickness insulation total screen standard thickness sheath, temperature resistant 125 ° C, 750V cable


Code meaning

Code

Code meaning

WDZ

Halogen-free low smoke flame retardant

DC

Product serial number

ZP

Total shielding

H

jacket

Installed in mineral-free and fuel-oil contaminated areas

Installed in contaminated mineral oil fuel oil (mineral oil and fuel oil)

125

125℃


Product performance standards

TB/T1484-2010    Q/HHTZH010-2012


Main Specifications

Cable transmittance: ≥80%        PH value: ≥4.3

Conductivity:≤10μs/mm         Halogen content: hydrogen chloride release ≤0.5%

Toxicity index:≤5                 Single cable vertical burning performance: in line with GB/T18380.12

Burning performance of bundled cable: Class C in accordance with GB/T18380.35-2008


Product structure diagram


WDZ-DC/Ⅲ-125 750V 240mm² Schematic

1.jpg

WDZ-DC-ZP-H/I-125 750V 10x1.5mm² Schematic

2.jpg

WDZ-DC-ZP-H/Ⅲ-125 750V 48x1.5mm² Schematic

3.jpg