use
This product is suitable for AC rated voltage of 750V and below. The distribution system, control system and signal system of various rolling stock and urban rail metro vehicles are especially suitable for use in small space and other electrical equipment with flame retardant requirements.
Conditions of Use
Cable rated working voltage U0/U: 450750V;
The long-term allowable operating temperature of the cable should not exceed 125°C.
Model and name introduction
model | Rated voltage | product name |
WDZ-DC/Ⅲ-125 | 750V | Low smoke zero halogen flame retardant standard wall thickness insulation, mineral oil and fuel oil resistant, temperature resistant 125 ° C, 750 V cable |
WDZ-DC-H/Ⅲ-125 | 750V | Low halogen-free flame retardant standard wall thickness insulation, standard thickness sheath, resistant to mineral oil and fuel oil, temperature resistant 125 ° C, 750 V cable |
WDZ-DC-ZP-H/Ⅰ-125 | 750V | Low smoke zero halogen flame retardant standard wall thickness insulation total screen standard thickness sheath, temperature resistant 125 ° C, 750V cable |
Code meaning
Code | Code meaning |
WDZ | Halogen-free low smoke flame retardant |
DC | Product serial number |
ZP | Total shielding |
H | jacket |
Ⅰ | Installed in mineral-free and fuel-oil contaminated areas |
Ⅲ | Installed in contaminated mineral oil fuel oil (mineral oil and fuel oil) |
125 | 125℃ |
Product performance standards
TB/T1484-2010 Q/HHTZH010-2012
Main Specifications
Cable transmittance: ≥80% PH value: ≥4.3
Conductivity:≤10μs/mm Halogen content: hydrogen chloride release ≤0.5%
Toxicity index:≤5 Single cable vertical burning performance: in line with GB/T18380.12
Burning performance of bundled cable: Class C in accordance with GB/T18380.35-2008
Product structure diagram
WDZ-DC/Ⅲ-125 750V 240mm² Schematic
WDZ-DC-ZP-H/I-125 750V 10x1.5mm² Schematic